It sounds counterintuitive, but a low refrigerant level drops the pressure inside the evaporator coil below freezing. Moisture in the air freezes on contact, building up ice on the indoor coil and the copper line set outside.
A lot of the service calls I get during peak summer come down to a system that just won't stop running. The AC runs for hours, struggles to reach the set temperature, and spikes the electric bill. The reason is often a too low refrigerant level.
Refrigerant doesn't get "used up" like gasoline in a car. It operates in a sealed loop. If your system is low on charge, it means there is a leak somewhere in the inside evaporator coil, in the copper lines, or in the outside condensing coil.
When refrigerant drops below its factory-specified level, the system loses its ability to absorb heat from your home effectively. The compressor works double-time trying to compensate, which drains power and accelerates wear on internal components.
4 Signs Your System Might Be Low on Refrigerant
Air from vents feels lukewarm: The air coming out of your supply vents should be 15°F to 20°F cooler than the air inside your home. If it feels room-temperature or barely cool, heat exchange isn't happening properly.
The AC struggles to maintain 70°F: If your indoor temperature creeps up to the high 70s when it's 100°F outside, the system runs much longer than it should, increasing your electricity bill.
The system runs non-stop: If your AC runs all afternoon without satisfying the thermostat setting, low pressure inside the system is likely preventing it from cooling at full capacity.
Ice on the outdoor line or indoor evaporator coil: It sounds counterintuitive, but a low refrigerant level drops the pressure inside the evaporator coil below freezing. Moisture in the air freezes on contact, building up ice on the indoor coil and the copper line set outside.
What to Do If You Notice These Signs
If you see ice on your lines or suspect a leak, turn the system off immediately.
Running a low-refrigerant unit continuously can overheat and damage the compressor, which is the most expensive component in your system. Let the ice thaw completely before a technician arrives.
When we inspect for low refrigerant, we recommend not to just "top off" the charge and leave the leak. Instead, we suggest to pressure-test the system, locate the leak, repair it properly, and weigh in the exact factory-specified charge so your system operates at peak efficiency.
Noticing any of these red flags? Contact us to schedule an inspection.